Roads - Tunnel
Field
Option
Scan inter-
Editable
val
fields
Scan Mode
Accuracy
optimised
Speed opti-
mised
Quick pro-
filer
TS handle is
Check box
attached
Radio han-
Normal han-
dle type
dle
Radio han-
dle
Description
c
e
Tunnel_014
a
Instrument axis
b
Ventilation shaft
c
Scan segment, included
d
Scan segment, excluded
e
Scan interval
Available for Define a scan task: Scan
whole profile. Defines at what interval to
measure a point around the profile.
This measurement mode is accuracy and
range optimized. It uses single distance
measurements to any surface.
This measurement mode is speed and per-
formance optimized. It uses continuous dis-
tance measurements to any surface.
It uses continuous distance measurements to
any surface. Stores the measured data once
the whole profile has been scanned or the
scan is paused.
☞
The Quick profiler mode does not
store TS observations.
When this box is checked, scanning a seg-
ment above the instrument is excluded auto-
matically. The TS handle would otherwise
interfere with measurements.
☞
If scanning at the station chainage,
then the scan does not include the
profile segment beneath the total
station.
If this option is selected, then it is not scan-
ned between 386 gon and 7 gon.
If this option is selected, then it is not scan-
ned between 380 gon and 25 gon.
d
b
a
817