Measure to line/Stake to line
Description of fields
Field
Option
Line
Display only
Start chain-
Display only
age
Chainage
Editable field
Distance
Editable field
along line
Offset
Editable field
Height off-
Editable field
set
Design
Editable field
height
Use stake
Check box
incre-
ments/Use
chainage
increments
Increment
Editable field
Increment
after stor-
ing
No
Increase
Decrease
Use differ-
Check box
ent incre-
ment on
curves
Increment
Editable field
Description
The name of the selected line.
The chainage of the start point of a line.
Chainage along the line. Define this value as
chainage of the start of the line plus a dis-
tance along the line.
Horizontal distance from the start point
along the line to the design point.
The offset from the line to the design point
The height offset of the design point.
For Height:Start point of line
The height of the design point is calculated
as the height of the start point plus
Height offset.
For Height:From line
The height of the design point is calculated
as the height of the reference point plus
Height offset.
For Height:User entered
The height of the design point is entered
manually.
Activates the use of stake/chainage incre-
ments.
Available when Use stake increments is
checked. Stake/chainage increment to be
used.
Sets behaviour of the stake/chainage after a
point is stored.
Does not change the stake/chainage after a
point is stored.
Proceeds to the next point up stake/chainage
after each stored staked point.
Proceeds to the next point down stake/
chainage after each stored staked point.
Option to use a different chainage increment
along a curve.
Available when Use different increment on
curves is checked. Chainage increment to be
used along the small radius curve.
589