Leica Captivate Technical Reference Manual page 613

Table of Contents

Advertisement

Grid Scan Settings,
Define grid spacing
on the plane.
Grid Scan Settings,
Define start point ID
& increment.
Grid Scan Settings,
Choose the grid scan
mode to be used.
Reference Plane & Grid Scan
Key
Description
ESC
To delete the last measured point of the rectangular or pol-
ygonal grid scan area. If necessary, remeasure scan area
points.
Description of fields
Field
Option
Left / right
Editable field
Up / down
Editable field
Grid scan
Display only
area
Estimated
Display only
points
Also meas-
Check box
ure the
boundary of
the defined
scan area
Description of fields
Field
Option
Start point
Editable field
Increment
Editable field
This panel is only displayed for motorised instruments. For all other instrument
types, the standard measurement mode is set.
Description
For tilted and vertical planes. Horizontal grid
distance.
Up slope grid distance.
Size of the grid scan area.
Estimated number of points to be grid scan-
ned.
>20'000 is shown for all resolution bigger
than 20'000 points.
It is not checked if all points from
the scan resolution fall within the
defined grid scan area. For more
than 20'000 points, grid scanning
the defined grid scan area with the
selected resolution may take long.
When this box is checked, the boundary of
the grid scan area is also measured.
Description
The point ID to start with.
The incrementation used for Start point. No
point ID template used
For Start point: RMS and Increment:
10 the points are RMS, RMS10,
RMS20, ..., RMS100, ...
For Start point: 100 and Increment:
10 the points are 100, 110, ..., 200,
210, ...
For Start point: abcdefghijklmn89 and
Increment: 10 the points are abcdef-
ghijklmn99, point ID incrementing fails.