Scan Mode
Scanning
Key
Description
Back
To return to the previous panel.
Description of fields
Field
Option
Define spac-
Angles
ing by
Distances
Hz and V
Editable field
Slope dis-
Editable field
tance
Horizontal
Editable field
spacing and
Vertical
spacing
Estimated
Display only
points
Next step
Next changes to the next panel.
Key
Description
Next
To accept and record the scan mode.
Distance
To measure and display distances.
Back
To return to the previous panel.
Description of fields
Field
Option
Select the
1000 pts/s,
appropriate
up to 300m
scan speed
& range.
250 pts/s,
up to 400m
62 pts/s, up
to 500m
Approx 1
pt/s, up to
1000m
Description
Horizontal and vertical angle values define
the scan resolution.
Horizontal and vertical spacings at a certain
range define the scan resolution.
Available for Define spacing by: Angles.
The horizontal and vertical angle values
defining the scan resolution.
Available for Define spacing by: Distances.
The range for which the horizontal and verti-
cal spacings are valid.
Available for Define spacing by: Distances.
The horizontal and vertical spacing defining
the scan resolution at the defined range.
The estimated number of points to be scan-
ned according to the defined scan resolution.
Description
1000 Hz scanning mode.
Range up to 300 m.
Optimal to use when time is critical.
250 Hz scanning mode.
Range up to 400 m.
Optimal for use when time and accuracy
are critical.
62 Hz scanning mode.
Range up to 500 m.
Optimal for use when accuracy and
range are critical.
1 Hz long range mode.
Range up to 1000 m.
Optimal for long range applications