49.3
Description
Important aspects
Monitoring prepara-
tion
Define Monitoring
Timer
Sets of Angles - TS

Monitoring

Monitoring is a module integrated within the Sets of Angles app.
Monitoring uses a timer to enable repeated and automated angle and distan-
ces measurements to pre-defined target points at defined intervals. The ability
to configure the handling of message panels during measurement sets is also
enabled.
For monitoring, instruments must be motorised.
This step-by-step description is an example on preparing a set for monitoring.
1.
Select the control job and the job.
2.
Set setup coordinates and setup orientation.
3.
Select Leica Captivate - Home: Measure sets.
4.
In Measure sets of angles press Fn Settings to configure Sets of
Angles for monitoring.
For the Parameters page set:
Stop for messages: All messages (for example purposes
only).
Time out: 10 secs (for example purposes only).
Define time when sets should be measured (timer moni-
toring) Select this option for monitoring. This setting enables
access to the Define Monitoring Timer panel.
5.
Press OK to access the Measure sets of angles panel.
6.
Select Create a new group.
7.
Press OK to access the Define Points for Set panel.
8.
Enter details of the target point as required.
For each target point, ensure that auto survey is activated. This set-
ting enables the automated measurement and recording of the tar-
get point in the other face. The setting also enables the automated
measurement and recording of all target points during monitoring.
9.
Press OK to access the Select Points - Measure panel.
10.
Measure and record the measurement to the target point as
required.
11.
Continue with steps 8. to 10. until all target points for the first
measurement set have been measured and recorded.
12.
Press Done to complete the selection of the target points for the
first measurement set in one face. This action then begins the meas-
urement of the target points in the other face. On completion, the
Measure sets of angles panel is accessed.
13.
Select Measure Sets.
14.
Press OK to access the Define Monitoring Timer panel.
Description of fields
Field
Option
Begin date
Editable field
Description
Start date for monitoring.
867