Setup Details - Leica Captivate Technical Reference Manual

Table of Contents

Advertisement

50.5
Access

Setup Details

878
Field
Option
Current
Display only
scale
Refer to "24 Antenna Heights" for further information regarding height values
used in a SmartStation.
Setup Details
Setup information must be typed in for Setup method: Resection, Setup
method: Orientate to line and Setup method: Orientate to object. Setup
Details is accessed after selecting OK in Total Station Setup with one of
these setup methods selected.
For a description of keys refer to "50.4 Choose Setup Point".
Description of fields
Field
Option
Point ID
Editable field
Instrument
Editable field
height
Point code
Selectable list
Choose tar-
Check box
get points
from a dif-
ferent job
Job
Selectable list
Manually
Check box
enter the
setup
height
Setup
Editable field
height
Line
between
target 1 & 2
defines
Description
Available when Scale TS measurements is
checked in Scale Corrections.
The scale according to the scale settings (Fn
Scale) for the selected setup.
Description
Type in an ID for the setup point.
The height of the instrument.
Select a point code for the setup point if
desired.
Available for setup method Resection and
Orientate to object.
Target points can be selected from the
design job.
The design job from which the target points
can be selected. Refer to "6.3 Choosing a
Job".
Available for setup method Orientate to
line.
When this box is checked, the height value
of the setup is entered and used to calculate
the height of the measured points.
When this box is not checked, the height of
the setup is calculated relative to the first
measured point. The height can be entered
in Measure Target.
Available for setup method Orientate to
line with Manually enter the setup height
being checked. The elevation of the instru-
ment setup.
Available for setup method Orientate to
line.
To define the positive North or positive East
axis.
Setup - TS

Advertisement

Table of Contents
loading

Table of Contents