Traverse Results - Leica Captivate Technical Reference Manual

Table of Contents

Advertisement

58.9
Description
Access

Traverse Results,

Position page
960
Field
Option
Northing
Display only
Height
Display only
Scale
Display only
Tempera-
Display only
ture
Pressure
Display only
Next step
IF accessed
after sets measurement
from Traverse Data
Traverse Results
Traverse closure results are displayed on this panel.
Is displayed automatically after the traverse closing point is measured or selec-
ted.
Key
Description
OK
To move to close angle, to survey a sideshot, to adjust the
traverse or to quit the Traverse app.
N & E or
To view the misclosure error in north/east or length/direction.
L & D
Adjust
To adjust the traverse.
Data
To display traverse data.
Description
Northing value of the setup position.
Orthometric height of the setup position.
Scale factor used in the calculation.
Temperature set on the instrument.
Atmospheric ppm set on the instrument.
THEN
OK opens a confirmation window with
options that depend on the traverse status:
For an open traverse:
Move to next setup, return to Point
Results, to survey a sideshot, to view tra-
verse data or to quit the Traverse app.
For a closed traverse:
Move to close angle, return to Point
Results, to survey a sideshot, to adjust
the traverse or to quit the Traverse app.
OK returns to Traverse Data.
Traverse

Advertisement

Table of Contents
loading

Table of Contents