22.3
Description
Access
Atmospheric Correc-
tions,
Atmospheric ppm
page
Settings - TS instrument

Atmospheric corrections

The settings on this panel define the atmospheric ppm and the refraction.
For standard applications, the distance is corrected due to atmospheric influen-
ces. The geometrical correction and the projection distortions are set to 0.00.
Heights are reduced with the standard refraction coefficient.
Refer to the product specific User Manuals for information on calculations.
Select Leica Captivate - Home: Settings\TS instrument\Atmospheric cor-
rections.
The atmospheric distance corrections are derived from the dry air temperature,
air pressure or elevation above mean sea level MSL, and the relative air humid-
ity or wet bulb temperature.
Key
Description
OK
To accept changes and return to Leica Captivate - Home.
Page
To change to another page on this panel.
Fn P<>E
To change Pressure to Elevation above mean sea level
and back.
Fn %<>T'
To change Humidity to Wet-bulb temperature and back.
Fn ppm=0
To set Atmospheric ppm: 0.0.
Description of fields
Field
Option
Tempera-
Editable field
ture
Pressure or
Editable field
Elevation
above mean
sea level
Humidity or
Editable field
Wet-bulb
tempera-
ture
Atmos-
Editable field
pheric ppm
or display
only
Description
Sets the temperature.
Sets the atmospheric pressure or the eleva-
tion above mean sea level dependent on
selection.
Sets the relative air humidity or the wet bulb
temperature dependent on selection.
The atmospheric ppm is either set or calcula-
ted from the values in the previous fields.