Sets of Angles - TS
Field
Option
Automatic
With lock
Visibility
Good
Rain & fog
Sun &
reflections
Use precise
Check box
target aim-
ing
Use ultra
Check box
fine aiming
Automati-
Check box
cally meas-
ure points
Next step
Measure to measure further sets of the selected points.
Motorised instruments point automatically in the direction of the targets.
Instruments with automatic aiming and auto survey activated, measure the
targets automatically.
Description
Positioning to static prisms. The ATRplus sen-
sor is used for measurements to static
prisms. If needed, an ATRplus measurement
or ATRplus search is performed after pressing
Measure or Distance.
The instrument locks onto and follows the
moving prism. The ATRplus sensor is used to
follow moving prisms and to find prisms after
loss of lock. Depending on the setting for
Measure distance, single or continuous
measurements are performed. Unavailable
for SmartStation.
Available when a CS20 is connected to a
TS15/TS50/TM50/MS50.
TS16/TS60/MS60 automatically adjust the
settings for optimal performance.
If weather conditions are normal, then select
this setting.
To increase the instrument measuring ability
during suboptimal weather conditions. This
setting is automatically deactivated when the
instrument is turned off.
To increase the instrument measuring ability
during incident solar radiation and reflec-
tions, for example safety vests. This setting
has a considerable influence on the range
(restriction 100 - 150 m). This setting is
automatically deactivated when the instru-
ment is turned off.
Available for instruments other than TS60/
TM50/TS50/TS30TS60. When this box is
checked, four ATRplus measurements are
performed and the mean value out the
measurements is considered for the angle
value.
Reduces the field of view of the ATRplus. The
setting is only applied for Aim at target:
Automatic.
Available for instruments with automatic aim-
ing and Aim at target:Automatic. If
checked, search and measurements are done
to specified targets in sets.
861