Check & Adjust,
Step 1
Settings - TS instrument
Key
Description
Measure
To measure the target.
Description of fields
Field
Option
Calibrate
Check box
the auto-
matic target
aiming
Calibrate
Check box
the tele-
scope cam-
era
1.
Aim the telescope accurately at
a target at a distance of about
100 m. The target must be posi-
tioned within ± 9°/± 10 gon of
the horizontal plane
The procedure can be
started in face I or II.
The fine aiming must
be performed man-
ually in both faces.
Measure to measure and to
continue to the next panel.
Description
When this box is checked, the determination
of the ATRplus horizontal and vertical adjust-
ment values is included.
Use a clean Leica standard prism
as target. Do not use a 360°
prism.
When this box is not checked, the determi-
nation of the ATRplus horizontal and vertical
adjustment value is excluded.
When this box is checked, the determination
of the telescope camera horizontal and verti-
cal zero point adjustment values is included.
In Cameras, Overview camera
page, Use TS overview camera
must be checked.
A prism is not required to run the
procedure.
Use a clean Leica standard prism
as target. Do not use a 360°
prism.