Renesas H8S/2100 Series Hardware Manual page 445

6-bit single-chip microcomputer
Hide thumbs Also See for H8S/2100 Series:
Table of Contents

Advertisement

(2)
At Transition from Smart Card Interface Mode to Software Standby Mode
1. Set the port data register (DR) and data direction register (DDR) corresponding to the SCK
pins to the values for the output fixed state in software standby mode.
2. Write 0 to the TE and RE bits in SCR to stop transmission/reception. Simultaneously, set the
CKE1 bit to the value for the output fixed state in software standby mode.
3. Write 0 to the CKE0 bit in SCR to stop the clock.
4. Wait for one cycle of the serial clock. In the mean time, the clock output is fixed to the
specified level with the duty ratio retained.
5. Make the transition to software standby mode.
(3)
At Transition from Software Standby Mode to Smart Card Interface Mode
1. Cancel software standby mode.
2. Write 1 to the CKE0 bit in SCR to start clock output. A clock signal with the appropriate duty
ratio is then generated.
[1] [2] [3]
Normal operation
[4] [5]
Figure 14.32 Clock Stop and Restart Procedure
Section 14 Serial Communication Interface (SCI)
Software
Normal operation
standby
[1]
[2]
Rev. 1.00 May 09, 2008 Page 419 of 954
REJ09B0462-0100

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8s/2112r

Table of Contents