ethernet cfm cc alarm-reset-time

Sets the time interval for identifying re-detection when CC repeatedly detects failures. If a
failure is detected within the time set by using this command after a failure has been
detected, the failure is treated as a re-detection and no trap is sent.
Note, however, that if a failure with a failure level higher than the currently detected failure
level is detected, a trap is sent.
Input format
To set or change information:
ethernet cfm cc level
To delete information:
no ethernet cfm cc level
Input mode
(config)
Parameters
level
<Level>
Sets the domain level that has been set by using the
command.
1.
2.
<No.>
ma
Sets the MA ID number that has been set by using the
vlan-group
VLAN ID by using the
1.
2.
alarm-reset-time
Sets the time for re-detecting a failure.
1.
2.
Default behavior
The maximum time for treatment as a re-detection is 10000 milliseconds.
<Level>
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
0 to 7
command. If the MA name has been set by using a character string or a
ma name
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
0 to 65535
<Time>
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
Multiples of 100 from 2500 to 10000 in milliseconds
<No.>
ma
alarm-reset-time
<Level>
ma
<No.>
alarm-reset-time
command, the parameter sets the MA ID number.
ethernet cfm cc alarm-reset-time
<Time>
ethernet cfm domain
command or the
ma name
ma
597