Ethernet Cfm Cc Alarm-Start-Time - Alaxala AX1250S Software Manual

Configuration command reference
Hide thumbs Also See for AX1250S:
Table of Contents

Advertisement

ethernet cfm cc alarm-start-time

Sets the time after CC detects a failure until a trap is sent.
Input format
To set or change information:
ethernet cfm cc level
To delete information:
no ethernet cfm cc level
Input mode
(config)
Parameters
level
<Level>
Sets the domain level that has been set by using the
command.
1.
2.
<No.>
ma
Sets the MA ID number that has been set by using the
vlan-group
VLAN ID by using the
1.
2.
alarm-start-time
Sets the time until a trap is sent following detection of a failure.
1.
2.
Default behavior
2500 milliseconds are used as the time until a trap is sent following detection of a failure.
Impact on communication
None
<Level>
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
0 to 7
command. If the MA name has been set by using a character string or a
ma name
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
0 to 65535
<Time>
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
Multiples of 100 from 2500 to 10000 in milliseconds
ma
<No.>
alarm-start-time
<Level>
ma
<No.>
alarm-start-time
command, the parameter sets the MA ID number.
ethernet cfm cc alarm-start-time
<Time>
ethernet cfm domain
ma name
command or the
ma
599

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax1240s

Table of Contents