storm-control
1.
action log
Outputs operation log data when a storm or the end of a storm is detected.
1.
filter-broadcast
When the flow rate of broadcast frames has a limit, this parameter sets the limit value
(lower threshold) as the number of broadcast frames that can be forwarded. The
frames exceeding the flow rate limit value are discarded. If 0 is set, all applicable
frames are discarded.
1.
2.
filter-multicast
When the flow rate of multicast frames has a limit, this parameter sets the limit value
(lower threshold) as the number of multicast frames that can be forwarded. The
frames exceeding the flow rate limit value are discarded. If 0 is set, all applicable
frames are discarded.
1.
2.
filter-unicast
When the flow rate of unknown unicast frames has a limit, this parameter sets the
limit value (lower threshold) as the number of unknown unicast frames that can be
forwarded. The frames that drop below the flow rate limit value (lower threshold) are
discarded. If 0 is set, all applicable frames are discarded.
1.
2.
filter-recovery-time
Sets the monitoring time for cancellation of the flow rate limit after flow rate limit has
gone into effect due to the detection of a storm. The monitoring time begins when the
number of received frames drops below the recovery-from-storm threshold, and the
flow rate limit is canceled when the time expires.
1.
2.
582
Default value when this parameter is omitted:
If a storm is detected, no SNMP traps are issued.
Default value when this parameter is omitted:
Operation log data is not output when a storm is detected.
<Packet/s>
Default value when this parameter is omitted:
When the flow rate has a limit, all broadcast frames are discarded.
Range of values:
0 to 10000000
<Packet/s>
Default value when this parameter is omitted:
When the flow rate has a limit, all multicast frames are discarded.
Range of values:
0 to 10000000
<Packet/s>
Default value when this parameter is omitted:
When the flow rate has a limit, all unknown unicast frames are discarded.
Range of values:
0 to 10000000
<Seconds>
Default value when this parameter is omitted:
The initial value is 1.
Range of values:
1 to 30 (seconds)