ethernet cfm cc alarm-priority
Table 31-1 Levels detected by CC and failures descriptions
Setting
Failure type
level
5
DefXconCCM
4
DefErrorCCM
3
DefRemoteCCM
2
DefMACstatus
1
DefRDICCM
0
none
Default behavior
Level 2 or higher failures are detected.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Notes
None
Related commands
ethernet cfm domain
ma name
ma vlan-group
596
Command
Failure description
display
OtherCCM
A CCM with a different domain and MA was
received.
ErrorCCM
A CCM with an incorrect MEP ID or transmission
interval was received.
Timeout
CCMs are no longer being received.
PortState
The port on the target Switch cannot communicate.
RDI
A CCM that reported the detection of a failure was
received.
Remote Defect Indication
--
No failure was detected.