Loop-Detection Threshold - Alaxala AX1250S Software Manual

Configuration command reference
Hide thumbs Also See for AX1250S:
Table of Contents

Advertisement

loop-detection threshold

Sets the number of L2 loop detections before a port is blocked. If the number of detections
becomes equal to or greater than the specified number, the port is blocked.
Input format
To set or change information:
loop-detection threshold
To delete information:
no loop-detection threshold
Input mode
(config)
Parameters
<Count>
Sets the number of L2 loop detections before a port is blocked.
1.
2.
Default behavior
The number of L2 loop detections before a port is deactivated is 1.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1.
When this command has been set and the parameter is changed, if any L2 loop
detections still remain, the change becomes operational only after the remaining
number of detections has been cleared.
Related commands
loop-detection enable
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
1 to 10000
<Count>
loop-detection threshold
591

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax1240s

Table of Contents