link debounce

Sets the link-down detection time after a link failure is detected until the actual link-down
occurs. When a large value is set for this command, temporary link-downs will not be
detected so the link will be prevented from becoming unstable.
Input format
To set or change information:
link debounce [time
To delete information:
no link debounce
Input mode
(config-if)
Parameters
time
<Milliseconds>
Sets the debounce timer value in milliseconds.
1.
2.
Default behavior
2000 milliseconds is set.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1.
If the link is stable even when a link-down detection time is not set, you do not need to
set one.
Related commands
None
<Milliseconds>
Default value when this parameter is omitted:
3000 milliseconds
Range of values:
Multiples of 100 from 0 to 10000 in milliseconds
]