rmon alarm

rmon alarm
Sets the control information for the RMON (RFC 1757) alarm group. A maximum of 128
entries can be configured.
Input format
To set or change information:
rmon alarm
rising-threshold
<Value>
[startup-alarm {rising-falling | rising | falling}]
To delete information:
no rmon alarm
Input mode
(config)
Parameters
<Number>
Sets the information identification number for the RMON alarm group control
information. This parameter is equivalent to
1.
2.
<Variable>
Sets the object identifier for the MIB used for checking the threshold. This parameter
is equivalent to
1.
2.
618
<Number> <Variable> <Interval>
<Value>
falling-event-index
<Number>
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
1 to 65535
alarmVariable
Default value when this parameter is omitted:
This parameter cannot be omitted.
Range of values:
Uses a maximum of 63 characters to set the MIB object identifier in dot
notation. Only the following specifiable object identifiers are valid:
Object name
-
See The setting range of object identifiers subject to alarm monitoring.
Instance number
-
x
in The setting range of object identifiers subject to alarm monitoring is
the instance number, which sets
range is as follows:
Fastethernet: Port number plus 9
Gigabitethernet: 58, 59
VLAN: VLAN ID plus 200
Link-aggregation: Channel group number plus 60
{delta | absolute}
rising-event-index
<Event#>
[owner
alarmIndex
defined in RFC 1757.
ifIndex
<Event#>
falling-threshold
<Owner string>
]
defined in RFC 1757.
of the MIB. The
ifIndex