rmon collection history
interval
Sets the time interval (in seconds) for collecting statistics information. This parameter
is equivalent to
1.
2.
Default behavior
None
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Notes
1.
To access an alarm group from the SNMP manager, you must register the SNMP
manager by using the
Related commands
interface
snmp-server community
624
<Seconds>
historyControlInterval
Default value when this parameter is omitted:
1800 (seconds)
Range of values:
1 to 3600 (seconds)
snmp-server community
defined in RFC 1757.