system fan-control
system fan-control
Enables the cooling fan control functionality, which operates by monitoring the internal
temperature.
Input format
To set information:
system fan-control
To delete information:
no system fan-control
Input mode
(config)
Parameters
None
Default behavior
The functionality is always enabled.
Impact on communication
None
When the change is applied
The change is applied immediately after setting values are changed.
Note, however, that when the
more than ten seconds for the change to be applied.
Notes
1.
This command applies only to the AX1240S-48T2C model.
2.
Even if this command is set, the cooling fan always operates for the first 10 minutes
after the Switch starts.
Related commands
None
68
no system fan-control
command is executed, it might take