Alaxala AX1250S Software Manual page 712

Configuration command reference
Hide thumbs Also See for AX1250S:
Table of Contents

Advertisement

Index
Message
ethernet : MA
<No.>
configured in cfm domain.
ethernet : MA name
already configured in cfm
domain.
ethernet : Maximum number of
entries are already defined.
<CFM_MA>
ethernet : Not found <Level>.
ethernet : Not found <No.>.
ethernet : Not found VLAN ID
in MA.
<VLAN ID>
ethernet : Too many parameters
(CFM_VLAN).
ethernet : VLAN ID
already configured in MA name.
interface : Can not delete it
because data is not
corresponding.
interface : Cannot change cfm
mep direction.
interface : Cannot configure cfm
enable to channel-group port.
interface : Cannot configure cfm
mep to channel-group port.
interface : Cannot configure cfm
mip to channel-group port.
interface : Domain level
is set with a value less than cfm
mep.
interface : Domain level
is set with values more than cfm
mip.
688
Explanation
is already
The specified MA identification number is already being used by
another domain.
<No.>: MA identification number
is
<Name>
The specified MA name is already set in the same domain.
<Name>: MA name
An attempt is being made to set a configuration that is larger than
the device capacity or to change a configuration in an environment
already at the maximum device capacity.
Delete configurations that are no longer used, and then set the
configuration again.
The specified domain level cannot be found. Make sure the domain
level has been set.
<Level>: Domain level
The specified MA identification number cannot be found. Make sure
the MA identification number has been set.
<No.>: MA identification number
The VLAN ID specified as the primary VLAN is not in the VLAN ID
list. Specify a VLAN ID that has already been set in the MA.
<VLAN
The number of input parameters exceeds the maximum number
(256). Set a value equal to or smaller than the maximum number.
is
<VLAN ID>
The specified VLAN ID is already being used by another MA name.
<VLAN
Deletion is not possible because the specified configuration does
not exist or duplicate data exists.
The MEP direction cannot be changed.
Delete the applicable command, and then set this again.
CFM of an interface participating in a port channel cannot be
enabled.
An MEP cannot be set for an interface that is participating in a port
channel.
An MIP cannot be set for an interface that is participating in a port
channel.
<Level>
A value equal to or smaller than the value set for the MEP is
specified for the specified domain level.
<Level>: Domain level
<Level>
A value equal to or greater than the value set for MIP is specified for
the specified domain level.
ID>: VLAN ID
ID>: VLAN ID

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax1240s

Table of Contents