Renesas RL78 Series User Manual page 454

16-bit single-chip microcontrollers
Hide thumbs Also See for RL78 Series:
Table of Contents

Advertisement

RL78/G1D
(2) Operation procedure
R01UH0515EJ0120 Rev.1.20
Dec 16, 2016
Figure 13-49. Initial Setting Procedure for Slave Transmission
Starting initial setting
Setting the PER0 register
Setting the SPSm register
Setting the SMRmn register
Setting the SCRmn register
Setting the SDRmn register
Setting the SOm register
Changing setting of the SOEm register
Setting port
Writing to the SSm register
Completing initial setting
CHAPTER 13 SERIAL ARRAY UNIT
Release the serial array unit from the
reset status and start clock supply.
Set the operation clock.
Set an operation mode, etc.
Set a communication format.
Set bits 15 to 9 to 0000000B for baud rate
setting.
Set the initial output level of the serial
data (SOmn).
Set the SOEmn bit to 1 and enable data
output of the target channel.
Enable data output of the target channel
by setting a port register and a port mode
register.
Set the SSmn bit of the target channel to 1
(SEmn bit = 1: to enable operation).
Initial setting is completed.
Set transmit data to the SIOp register (bits
7 to 0 of the SDRmn register) and wait for
a clock from the master.
433

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rl78/g1dR5f11aggR5f11aghR5f11agj

Table of Contents