(b) When operation starts with slave channel output mode (TOM0p = 1) setting (PWM output))
When slave channel output mode (TOM0p = 1), the active level is determined by timer output level register 0
(TOL0) setting.
TOEmp
Hi -Z
TO0p
(output)
Port output is enabled
Remarks 1. Set:
Reset:
2. p: Channel number (p = 1 to 7)
R01UH0515EJ0120 Rev.1.20
Dec 16, 2016
Figure 7-32. TO0p Pin Output Status at PWM Output (TOM0p = 1)
Active
Default
status
Reset
Set
The output signal of the TOmp pin changes from inactive level to active level.
The output signal of the TOmp pin changes from active level to inactive level.
CHAPTER 7 TIMER ARRAY UNIT
Active
Active
Reset
Set
Set
TO0p bit = 0
(Default status : Low)
TOL0p bit = 0
(Active high)
TO0p bit = 1
(Default status : High)
TO0p bit = 0
(Default status : Low)
TOL0p bit = 1
(Active low)
TO0p bit = 1
(Default status : High)
205