13.1.3 Simplified I
C (IIC00, IIC20)
This is a clocked communication function to communicate with two or more devices by using two lines: serial clock
(SCL) and serial data (SDA). This simplified I
flash memory, or A/D converter, and therefore, it functions only as a master.
Make sure by using software, as well as operating the control registers, that the AC specifications of the start and stop
conditions are observed.
For details about the settings, see 13.7 Operation of Simplified I
[Data transmission/reception]
● Master transmission, master reception (only master function with a single master)
● ACK output function
● Data length of 8 bits (When an address is transmitted, the address is specified by the higher 7 bits, and the least
significant bit is used for R/W control.)
● Manual generation of start condition and stop condition
[Interrupt function]
● Transfer end interrupt
[Error detection flag]
● ACK error, or overrun error
* [Functions not supported by simplified I
● Slave transmission, slave reception
● Arbitration loss detection function
● Wait detection functions
Note When receiving the last data, ACK will not be output if 0 is written to the SOEmn bit (serial output enable register
m (SOEm)) and serial communication data output is stopped. See the processing flow in 13.7.3 (2) for details.
Remark m: Unit number (m = 0, 1), n: Channel number (n = 0)
R01UH0515EJ0120 Rev.1.20
Dec 16, 2016
2
C is designed for single communication with a device such as EEPROM,
Note
and ACK detection function
2
C]
CHAPTER 13 SERIAL ARRAY UNIT
2
C (IIC00, IIC20) Communication
370

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rl78/g1dR5f11aggR5f11aghR5f11agj

Table of Contents