Switching Continuous Tone Detection At End Of Call On/Off; Switching Loop Current Detection At End Of Call On/Off - Auerswald COMpact 3000 analog Installation, Operation And Configuration Instructions

Hide thumbs Also See for COMpact 3000 analog:
Table of Contents

Advertisement

Configuring and Managing the PBX
Analog Connection

Switching Continuous Tone Detection at End of Call On/Off

Switching Continuous Tone Detection at End of Call On/Off
If continuous tone detection is enabled, the network provider sends a continuous tone via the
PBX; this signal is interpreted as the end of the call connection.
Switching this on/off can be done as follows:
• Via the configuration manager
Requirements:
– External analog port (only COMpact 3000 analog)
– Network provider support for the continuous tone at the end of a call
– Configuration manager, opened with sufficient authorization
– Expert view (click
– Configured prefixes (country prefix and local area code)
1. Open the page CONFIGURATION > External numbers.
2. In the list field at the top, select the analog connection.
A page opens for configuring the analog connection.
3. Open the page Analogue connection > Expert configuration.
4. Select or clear the Continuous tone check box under End of the call.
Enables continuous tone detection.
Disables continuous tone detection.
Further steps:
– Save your settings before you leave the page.

Switching Loop Current Detection at End of Call On/Off

If loop current detection at the end of a call is enabled, a reduction of the loop current to zero
by the PBX network provider is interpreted as the end of the call.
Switching this on/off can be done as follows:
• Via the configuration manager
378
)
COMpact 3000 analog/ISDN/VoIP - Firmware Version 4.0 - Version of the Manual 03 02/11