Installation
• Pull out the PBX's power plug before instructing a qualified electrician to open the
casing, to install the expansion modules, or to switch or connect equipment. Also
disconnect the device from additional power sources (e. g. UPS, if installed).
• Wait at least 3 minutes for the discharge of any capacitor in the device after
disconnecting it from the main power supply.
Important: Improper use can cause, for example, functional restrictions or
interference, the destruction of the device or, in a worst-case scenario, personal injury.
• Only connect equipment that is compatible with the proper use of the PBX.

Installation Instructions

The PBX is intended to be operated in closed rooms. In addition, all of the devices connected
to the system must be located inside the building.
The PBX enables you to connect some devices directly, inasmuch as they are close enough
to the PBX. The distance depends on the length of the equipment connection cables up to a
maximum of 10 m.
If no suitable connection sockets are available or are too far away, you must lay the
installation cable permanently. Use installation cable (e. g. J-Y(St)Y 2x2x0.6) with the
following characteristics:
Unscreened; however: screened for unfavourable conditions, for example, near a strong
transmitter or an electrical power line
only for ISDN: preferably star quad stranding
ISDN: When assigning the individual wires, orientate yourself with the identifiers
subsequently listed or refer to VDE 0815 when identifiers deviate.
Physical circuit/
pair 1
Physical circuit/
pair 2
Analogue/U
: Prevent interferences. Avoid laying long lengths of parallel lines, especially
P0
next to the mains. Twist the pairs.
Accessories and service parts can be bought at specialised stores.
Network Provider at the External S
Connection possibilities:
NTBA
Digital GSM gateway
Router with internal S
VoIP/ISDN adapter
52
Cable with Two Twin Wires
a1
red
b1
black
a2
white
b2
yellow
Port
0
port
0
Cable with Star Quad
without ring
single rings, 17 mm spacing
double rings, 34 mm spacing
double rings, 17 mm spacing
COMpact 5200/5200R/5500R - Instructions V03 03/2019