Status Displays; Status Displays On The Leds - Auerswald COMpact 3000 analog Installation, Operation And Configuration Instructions

Hide thumbs Also See for COMpact 3000 analog:
Table of Contents

Advertisement

Service and Maintenance

Status Displays

Status Displays on the LEDs

Status Displays
To control the operating state, the PBX provides various status displays.
Status Displays on the LEDs
The LED display field on the unit is used to keep track of the operating state.
Note: If ECO mode (Energy Savings Function) is enabled, all of the LEDs are
disabled and no display is possible. Exception: In only "Power" LED on ECO
mode, all of the LEDs, except for the "Power" LED, are disabled. This is not
lit constantly, but flashes slowly in green.
"Line" LED:
Off
Lit in green
Flashes green
Flashes orange
Lit in orange
"Messages" LED:
Off
Lit in green
Flashes green
Flashes red
"WAN" LED:
Off
Lit in green
Flashes green
492
Operational/busy state of the existing exchange lines
At least one call channel is not ready. (This overridden by
display of the busy state.)
All call channels are ready and available.
COMpact 3000 VoIP: The connection to a modem (DSL, cable,
sat) exists. No VoIP account has been registered.
At least one call channel is being used.
All call channels are being used.
Status of the message memory:
There are no messages.
There are no new messages. All existing messages have been
viewed, but not yet deleted.
There is at least one new message that has not yet been read.
The message memory is full.
Status of the Ethernet interface (only for the COMpact 3000
VoIP, Ethernet port WAN):
No Ethernet connection to a computer/network exists.
An Ethernet connection to a computer/network exists.
An Ethernet connection exists and packets are being trans-
mitted.
COMpact 3000 analog/ISDN/VoIP - Firmware Version 4.0 - Version of the Manual 03 02/11