Configuring and Managing the PBX
Identification
Configuring the Gateway
Configuring Gateway via the Configuration Manager
Requirements:
– Configuration manager, opened with sufficient authorization
– Disabled DHCP client
1. Open the page CONFIGURATION > Server configuration > Network.
Note: The configuration is also provided during the quick configuration using
the configuration wizard.
2. In the Gateway entry field under Ethernet configuration, enter the IP address of the
gateway. The following entries are possible:
IP address with a range of 0 to 255 (example: 192.168.0.2)
Further steps:
– Save your settings before you leave the page.
Configuring the Gateway via an Internal Telephone
Requirements:
– Disabled DHCP client
– Knowledge of the sub-admin or admin PIN
1. Pick up the receiver.
2. Dial ##8.
3. Enter the sub-admin or admin PIN.
4. Dial *933*.
5. Enter the IP address of the gateway. The following entries are possible:
12 digits (e.g.: for the IP address 192.168.0.2, enter 192168000002)
6. Dial #.
7. Hang up the receiver.
342