Maintenance-Object Repair Procedures
Table 8-206. Test #7 Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
PASS
The port can correctly conference multiple connections. Investigate
user-reported troubles on this port using other port tests and by examining
station, trunk, or external wiring.
0
NO
The test could not relate the internal ID to the port. This could be due to
BOARD
incorrect translations, no board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Verify that the board's translations are correct. Use the lIst config
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
8-512
Issue 1 May 2002
command, and resolve any problems that are found.
board command.
This should re-establish the link between the internal ID and the port. If
not, check to see that there is a valid board inserted.
Continued on next page