Maintenance-Object Repair Procedures
n. Error Type 2306: too many parity errors in data received from the
LAN/packet bus.
1. Run test board UUCSS.
o. Error Type 2561: Packet Interface Loop Around test (#598) failure. The
ATM-TRK circuit pack has failed, the packet bus has a minor alarm active,
or the packet bus is out of service.
1. Run test board UUCSS.
p. Error Type 2817, 2818: DSP failure detected along the circuit path.
1. Run test board UUCSS.
2. Follow the repair procedures suggested for Test #1293.
8-282
Issue 1 May 2002
If
Test 598 fails.
Follow the repair procedures suggested for that
Test 598 passes
See
There are no errors
against the packet
bus MO
If
Test 598 fails
Follow the repair procedures suggested for that
Test 598 passes
See
There are no errors
against the packet
bus MO
Error Type
Description
2818
One or more DSPs failed. The Aux Data field contains
the ID number of DSP that failed
2817
DSP test failure. The Aux Data field contains the
following information about the failed DSPs:
X is the number of talker DSPs
Y is the number of listener DSPs
Z is the number of echo-cancelling DSPs
Then
test.
''PKT-BUS (Packet Bus)''
specified repair.
This can be a transient condition. Do nothing
now, but escalate if the error occurs repeatedly.
Then
test.
''PKT-BUS (Packet Bus)''
specified repair.
This can be a transient condition. Do nothing
now, but escalate if the error occurs repeatedly.
and perform the
and perform the