Maintenance-Object Repair Procedures
Looparound and Conference Circuit Test (#33)
This test checks the reflective loop-around and conference capabilities of a CO
port circuit. The test uses 404-Hz, 1004-Hz, and 2804-Hz tones. Each tone is
transmitted separately through the loop and checked.
Table 8-188. Test #33 Looparound and Conference Circuit Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
7
ABORT
Conference Circuit test aborted.
129
ABORT
The 404-Hz reflective loop-around test aborted. Response to the test request
was not received within the allowable time period.
131
The 1004-Hz reflective loop-around test aborted. Response to the test request
was not received within the allowable time period.
133
The 2804-Hz reflective loop-around test aborted. Response to the test request
was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. If the port status is active but the port is idle (no calls), check the error log
3. If the port status is idle, retry the command at 1-minute intervals up to 5
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
8-468
Issue 1 May 2002
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle before testing.
for error type 769 (see the error log table for a description of this error and
required actions). The port may be locked up.
times.
retry the command at 1-minute intervals up to 5 times.
times.
Continued on next page