Maintenance-Object Repair Procedures
Table 8-335. Test #1413Firmware Download Test — Continued
Error
Test
Code
Result
Description / Recommendation
7
FAIL
The source board entered on the screen is absent.
Execute the display firmware download command and verify the source
board location.
Verify the source boards translations.
If the location is incorrect, execute the change firmware download command
and enter the correct location on the screen
8
FAIL
The source boards entered on the screen are incorrect. The board could have
been changed after the schedule was entered.
Execute the list config command. verify the source board location.
Execute the change firmware download command and enter the correct
location on the screen.
PASS
Firmware download to this circuit pack is successful.
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
Ensure that the board translations are correct.
If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If so, the board was shut down.
Reseating the board will re-initialize it.
If the board was found to be correctly inserted in step 1, then issue the
busyout board UUCSS command.
Issue the reset board UUCSS command.
Issue the release board UUCSS command.
Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and the port.
8-882
Issue 1 May 2002
Continued on next page