Maintenance-Object Repair Procedures
NPE Crosstalk Test (#6)
The NPE Crosstalk test verifies that this port's NPE channel talks on the selected
time slot and never crosses over to time slots reserved for other connections. If
the NPE is not working correctly, one way and noisy connections may be
observed. This test is usually only part of a port's long test sequence and
executes in approximately 20 to 30 seconds.
Table 8-187. Test #6 NPE Crosstalk Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. If the port status is active but the port is idle (no calls), check the error log
3. If the port status is idle, busyout and release the trunk, and retry the
4. If the test still aborts, replace the circuit pack.
1001
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
8-466
Issue 1 May 2002
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle before testing.
for error type 1025 (see the error log table for a description of this error and
required actions). The port may be locked up. Check the CO wiring, check
for excessive loop current, and check the trunk translations. (If the trunk is
translated incorrectly, this test will abort.)
command at 1-minute intervals up to 5 times.
retry the command at 1-minute intervals up to 5 times.
times.
Continued on next page