Avaya S8700 Maintenance Manual page 841

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

AN-LN-PT (Analog Line Port)
Table 8-45. Test #161 Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
0
NO
The test could not relate the internal ID to the port (no board). This result could
BOARD
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use the list
2. If the board is correctly inserted, issue the busy board UUCSS command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command.
555-233-143
configuration command, and resolve any problems.
This should re-establish the link between the internal ID and the port. If
not, verify that a valid board is inserted.
Continued on next page
Issue 1 May 2002
8-119

Advertisement

Table of Contents
loading

Table of Contents