Avaya S8700 Maintenance Manual page 1312

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-239. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
1320
Any
Loss of Signal Alarm
Inquiry test (#138)
1321
Any
Loss of Signal Alarm
Inquiry test (#138)
1322
Any
Loss of Signal Alarm
Inquiry test (#138)
1323
Any
Loss of Signal Alarm
Inquiry test (#138)
1324
Any
Loss of Signal Alarm
Inquiry test (#138)
1538 (q)
Any
1793
Any
Blue Alarm Inquiry test
(#139)
1794
Any
Blue Alarm Inquiry test
(#139)
1795
Any
Blue Alarm Inquiry test
(#139)
2049
Any
Red Alarm Inquiry test
(#140)
2305
Any
Yellow Alarm Inquiry test
(#141)
2306
Any
Yellow Alarm Inquiry test
(#141)
2561
Any
Major Alarm Inquiry test
(#142)
2817
Minor Alarm Inquiry test
(#143)
3073 to
Any
Slip Alarm Inquiry test
3160 (r)
(#144)
3329 to
Any
Misframe Alarm Inquiry
3345 (s)
test (#145)
3840(t)
Any
None
3900(u)
Any
CPE Loopback Jack test
(#1212)
8-590
Issue 1 May 2002
On/Off
Alarm Level
Board
MINOR
OFF
WARNING†
MINOR
OFF
WARNING†
MINOR
ON
MINOR
OFF
WARNING†
WARNING
OFF
MINOR
ON
MAJOR
OFF
MINOR
WARNING **
MAJOR
OFF
MINOR
WARNING **
MAJOR
OFF
MINOR
WARNING **
MINOR
OFF
WARNING†
MINOR
OFF
MINOR
OFF
MINOR
OFF
WARNING†
MINOR
OFF
WARNING†
MINOR
OFF
WARNING†
MINOR
OFF
WARNING†
Test to Clear Value
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS
test board UUCSS r 6
test board UUCSS r 6
Continued on next page