Avaya S8700 Maintenance Manual page 1662

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-365. Test #1379 Ping Test — Continued
Error
Test
Code
Result
Description / Recommendation
2805
FAIL
The number of pings received did not match the number sent (normally one
ping sent). This means that no ping responses were received from the
gateway defined on the ip-interfaces form for the Media processor.
1. Retry the command at 1-minute intervals up to 3 times.
2807
ABORT
The board is administered but not enabled in the change ip-interfaces form.
7, 89,
FAIL
A ping to the destination failed through this port. This failure is because the
1007
destination is down.
1. Verify that at least one destination is reachable through this port.
2. Once verified, execute the test port UUCSSpp command to verify that the
PASS
Ping through this port is successful.
MP Diagnostic Test (#1406)
This test is destructive.
The MP Diagnostic test (#1406) runs all of the diagnostic tests listed below, in the
order listed, but only if each successive test passes:
1. FPGA Query
2. TSI Query
3. ETHERNET Query
4. SCOTCH Sanity
FPGA Query
This test passes if the FPGA device on the TN2302 tests okay. Otherwise, it fails
with no fail code or AUX data.
This test verifies the status of the FPGA device on the TN2302 circuit pack. If the
device is bad, software sets an appropriate counter, posts an error and alarm, and
takes all DSPs out of service (all DSPs are controlled by the one FPGA).
Software then attempts to reset the FPGA. If the reset passes or the original test
passes, the DSPs are placed into service.
8-940
Issue 1 May 2002
H.323 Signaling Group Ping test (#1387) passes.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents