H323-SGRP (323 Signaling Group)
Table 8-342. Test #1387 H.323 Signaling Group Ping Test — Continued
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test was not received from the C-LAN circuit pack within the
allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABORT
The necessary system resources to execute the test could not be allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3times.
2800
ABORT
No C-LAN in the same region.
1. Verify translations and retest.
2801
ABORT
No IP address defined.
1. Verify translations and retest.
2802
ABORT
Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
7, 89,
FAIL
PING to the destination failed through this port because the destination was
1007
down.
1. Verify that at least one destination reachable through this port is "up".
PASS
PING through this port was successful.
555-233-143
ports on the board are idle (amber LED is off). Reset the circuit pack by
issuing the busyout board UUCSS, reset board UUCSS, and release
board UUCSS commands.
Once verified, execute test sig-group grp# command to verify that the
H.323 Signaling Group Ping test (#1387) passes.