Avaya S8700 Maintenance Manual page 1019

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ATM-TRK (Circuit Emulation Service Circuit Pack)
ATM Board Time Of Day Update (#1261)
The nondestructive ATM-TOD-UPD test updates the system time used by the
ATM-TRK circuit pack for SDH/SONET performance monitoring and synchronizes
the ATM-TRK circuit pack with the S8700 Multi-Connect system's clock. This test
is run during initialization, scheduled maintenance, and craft long test.
Table 8-130. ATM Board Time Of Day Update (#1261)
Error
Test
Code
Result
Description / Recommendation
2031
FAIL
The attempt to send the message to the ATM-TRK circuit pack was not
successful.
2500
FAIL
Internal system error. Did not send the time-of-day information to the board.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test aborts with the same error code, escalate the problem.
PASS
The ATM-TRK circuit pack is successfully updated with system time.
1. If the status port-network command still indicates that this link is down, it
2. If the link still does not come up, reset one or both ATM-TRK circuit packs
0
NO
No board detected.
BOARD
1. Check the error log for wrong board (Error 125) or no board (Error 131).
2. Check that the board is properly translated and inserted. If so, check for
1. Run the test again. If it fails, the board could be bad. Replace the board
555-233-143
is possible that one or both of the ATM-TRK circuit packs have been
busied out.
on the link.
Resolve either of these issues, if applicable.
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
and retest.
Continued on next page
Issue 1 May 2002
8-297

Advertisement

Table of Contents
loading