Maintenance-Object Repair Procedures

CONFIG (System Configuration)

MO's Name (in
Alarm Log)
CONFIG
The System Configuration MO oversees logical insertion and removal of circuit
packs in the system. When Switch Control detects that a circuit pack is present in
a port slot, it informs System Configuration and System Configuration queries the
circuit pack to determine the type and vintage of the circuit pack. Similarly, when
Switch Control detects that a circuit pack has been removed from a port slot, it
informs System Configuration.
There are no alarms or tests for System Configuration, but three types of errors
are logged to the Hardware Error Log.
Error Log Entries and Test to Clear Values
Table 8-191. System Configuration Error Log Entries
Error
Aux
Type
Data
1
0
0
1-119 (a)
0-21
257(b)
1001-111
0-21
9 (c)
1.
This error should not occur. It indicates that an attempt was made by software to raise an alarm against CONFIG
without first logging a CONFIG error.
Notes:
a. This error indicates that a port circuit pack in the system did not respond to
a circuit pack type inquiry. Follow the procedures outlined in (b) to
determine whether there is an error.
b. This error indicates that less than 25% of trunk group is available.
c. This error indicates that a port circuit pack in the system did not respond to
a vintage inquiry.
As a result of either of these errors, a port circuit pack may be physically
inserted in a port slot, but the system may not recognize its existence. The
Aux Data field specifies the circuit pack's port-network number as
indicated in the following table.
8-476
Issue 1 May 2002
Alarm
Level
Initial Command to Run
none
none
Alarm
Associated Test
Level
none
none
none
none
MAJOR
none
Full Name of MO
System Configuration
On/Off
Board
Test to Clear Value
N/A