BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Table 8-144.
Test #618 BRI Port Local LAN Loop Around — Continued
Error
Test
Code
Result
Description / Recommendation
1139
ABORT
The EPN's packet bus is out-of-service.
1. Follow the repair procedures for the packet bus.
2. After completing step 1, execute the test port long PCSSpp command,
1141
ABORT
The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. After completing step 1, execute the test port long PCSSpp command,
2012
ABORT
Internal system error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
FAIL
The Loop Around test has failed.
1. If the test fails repeatedly, attempt to reset the circuit pack if the other ports
2. If the test fails again, execute test port-network pn#. If this fails, follow
3. If tests executed in step 2 pass, the problem is local to the BRI board.
PASS
The BRI Port Local LAN Loop Around test has passed.
BRI Port Local TDM Loop Around Test (#619)
This test is destructive.
This test verifies the connectivity of a BRI port across the TDM Bus. It aborts if
calls associated with the port are in progress. Failure of this test indicates an
on-board fault associated with the port hardware on the circuit pack.
555-233-143
and review the results of the BRI Port Local LAN Loop Around test to verify
the repair.
and review the results of the BRI Port Local LAN Loop Around test to verify
the repair.
on the board are idle. Reset the circuit pack by issuing the busyout board
PCSS and the reset board PCSS commands.
failure procedures in
''PKT-BUS (Packet Bus)'' on page
Replace the circuit pack.
8-1230.
Continued on next page
Issue 1 May 2002