Avaya S8700 Maintenance Manual page 1670

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-368. Long IP 2Way Transmission Test (#1506)
Error
Test
Code
Result
Description / Recommendation
1002
ABORT
The system could not allocate timeslots for the test. The system may be under
heavy traffic conditions or it may have timeslots out of service due to TDM-BUS
errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, retry
2. If system has TDM-BUS errors, clear any errors, and retry the command at
3. If the command continues to abort, escalate the problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors. Even without TTR-LEV errors, a Tone
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 3
2000
ABORT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2012
ABORT
Generic system call failed. Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2801
ABORT
The IP Media processor board has not been administered on the ip-interfaces
form.
2804
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2806
ABORT
The system could not find any in-service IP Media processor boards to use as
a destination for this test.
2806
ABORT
The system could not find any in-service IP Media processor boards to use as
a destination for this test.
8-948
Issue 1 May 2002
the command at 1-minute intervals up to 3 times.
1-minute intervals up to 3 times.
Detector could be unavailable in the PN containing the circuit pack being
tested. Verify that at least one Tone Detector resides in this PN. If not, the
test always aborts for this circuit pack, but does not harm the system.
times.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents