Avaya S8700 Maintenance Manual page 846

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-46. Announcement Circuit Pack Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
2817(j)
Announcement
Checksum test (#209)
17682
In-line Error
1769(j)
In-line Error
3840(l)
Any
None
3999(o)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. Error Type 1
functioning or it was physically removed from the system.
If the circuit pack is not in the system, insert a circuit pack (in the same slot
as the error indicates) to resolve this error. If the circuit pack is in the
system and the red LED is on, see
with Error Type 1'' on page
b. Error Type 14
Checksum test (#209) fails. The Aux Data indicates the identifying number
of the first defective announcement found. This number corresponds to the
announcement numbers on the announcement administration form. The
extension associated with the announcement can be determined with the
display announcement command. This error always appears in
conjunction with Error Type 2817. Follow the procedures for Error Type
2817 to troubleshoot Error Type 14.
c. Error Type 23
physically installed. The alarm clears when the circuit pack is installed.
d. Error Type 125
circuit pack is logically administered. To resolve this problem, either
remove the wrong circuit pack and insert the logically administered circuit
pack OR use the change circuit-pack command to re-administer this slot
to match the circuit pack inserted.
8-124
Issue 1 May 2002
Alarm Level
MINOR
This error indicates the circuit pack totally stopped
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed or when the SAKI test (#53) fails.
6-5.
This error is logged whenever the Announcement
The circuit pack has been logically administered but not
A wrong circuit pack is inserted in the slot where this
On/Off
Board
Test to Clear Value
ON
test board UUCSS sh r 3
Continued on next page
''LED Alarms without Alarm Log Entry or
555-233-143

Advertisement

Table of Contents
loading