Avaya S8700 Maintenance Manual page 1217

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

DAT-LINE (Data Line Port)
Table 8-201. Test #171 Digital Loop-Around Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1000
ABORT
System resources required to run test are not available. The port may be in
use on a valid call. Use status data-module to determine when the port is
available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1020
ABORT
An existing Error Type #769 on this port prevented the test from running.
1. Follow the procedure following the Error Log Table for Error Type #769.
1042
ABORT
Port under test is a TTI port and has only default translations with no assigned
extension. The executed test requires an assigned extension associated with
the port being tested. Therefore, this test cannot successfully execute.
1. If there is a need to execute the test on this particular port, then the tester
1180
ABORT
There is no Maintenance/Test circuit pack digital port available to carry out the
test.
1. Check to see if the Maintenance/Test digital ports are present. (Enter list
2. If the digital ports (02 and 03) on the Maintenance/ Test circuit pack are not
3. If the digital ports are present, retry the command at 1-minute intervals up
1181
ABORT
No time-slots available to connect digital ports for the test.
1182
ABORT
Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1340
ABORT
No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test digital ports
2. Look for M/T-DIG errors in the Error Log. If present, see
3. If the ports are present and no errors are logged against them, retry the
4. If the test continues to abort, replace the Maintenance/Test circuit pack.
555-233-143
must ensure that the port is fully translated such that the port has an
assigned extension.
config command; ports 02 and 03 should show).
present, see
''M/T-BD (Maintenance/Test Circuit
to 5 times.
(ports 02 and 03 on the Maintenance/Test circuit pack) are present in the
system. At least one Maintenance/Test circuit pack must be present in PN
1 of the system. There should be at least two such ports present. If the
ports are present, proceed to step 2. Otherwise, determine why no ports
appear in the list config display. Refer to "M/T-DIG" and "M/T-BD".
(Maintenance/Test Digital
command at 1-minute intervals up to 5 times.
Pack)''.
Port)''.
Continued on next page
Issue 1 May 2002
''M/T-DIG
8-495

Advertisement

Table of Contents
loading

Table of Contents