Avaya S8700 Maintenance Manual page 922

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-83. Error type 1281 Aux Data and repair procedures — Continued
Aux
Alarm
Data
Description
23
High-level path
Remote defect
Indicator: HP_RDI
24
Loss of cell
delineation (LCD)
27
SIGCON_DOWN
ATM switch high
level signal.
l. Error Type 1537 — LAN bus time out. The circuit pack is transmitting a
packet larger than 1,024 bytes. Replace the circuit pack.
m. Error Type 1538 — A hyperactive ATM-EI circuit pack is generating an
abnormal amount of control messages to the processor. When this error is
generated, the system automatically resets the ATM-EI.
Duplicated PNC?
Y
N
8-200
Issue 1 May 2002
Repair procedure
The far end is detecting a major problem with the signal that this
board is transmitting. The transmitted payload is invalid.
Make sure the ATM switch port (or a MUX port, if present between
ATM switch and the ATM-EI board) is the same as the ATM-EI
circuit pack's cable interface.
Run test board UUCSS command; if the Test #1259 fails with Error
Code 23, connect a fiber back-to-back in a looped mode (one strand
of fiber connecting the transmit transceiver to the receive
transceiver of the board) and see if the amber LED flash goes away.
If it does the problem is off-board.
If the amber LED continues to flash, replace the circuit pack.
On board ATM framer chip is not able to frame cells based on the
cell header.
Reset the board (reset board UUCSS).
If the error persists, replace the board.
The board cannot communicate with the ATM switch.
Busyout the board (busyout board UUCSS).
Test the board (test board long UUCSS).
If Test #1260 fails, replace the board.
If Test #1260 passes, make sure the ATM address on both the
S8700 Multi-Connect
and the ATM switch sides are the same for
this board.
If the address is the same, change the port on the ATM switch side.
This could require administration on the ATM switch.
If the error is resolved, the problem is on the ATM switch port.
Then:
service to the EPN is disrupted
the system switches to the standby PNC
Continued on next page
555-233-143

Advertisement

Table of Contents
loading