Table 8-210. Test #33 Loop-Around and Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
3
FAIL
The nonreflective 1004-Hz tone test of the port failed. An echo was detected
from the port. Poor-quality transmission was detected to or from the port.
The problem may be off-board.
7
The conference capabilities of the port failed. Poor-quality transmission was
detected to or from the port. The problem may be off-board.
129
The reflective 404-Hz tone test failed. Poor-quality transmission was detected
to or from the port. The problem may be off-board.
131
The reflective 1004-Hz tone test failed. Poor-quality transmission was
detected to or from the port. The problem may be off-board.
133
The reflective 2804-Hz tone test failed. Poor-quality transmission was
detected to or from the port. The problem may be off-board.
8-524
Issue 1 May 2002
!
CAUTION:
The port may still be operational, or the fault may be off-board
(connections or CO). Off-board problems include incoming
seizures or off-hook port seizures during the test and, perhaps,
noise induced by adjacent electric power lines. The test may be
disabled from trunk administration 'Test' field. This turns off all
testing for that trunk group except for tests 6 and 36.