Avaya S8700 Maintenance Manual page 1678

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-375. Encoding of Error Codes for Software Requested IPSI interchange
Field
Variable Name
y
Fault class/stimulus
causing software action
z
Fault or improvement
AUX DATA Descriptions
Table 8-376. Aux Data Descriptions for Software-Requested Interchange
Aux
Data
Description
0
No specific extra information is available
10
Interchange from B-side to A-side IPSI (possible preference switch)
20
Interchange from A-side to B-side IPSI
30
Control (archangel) moves from A-side IPSI to EI
40
Interchange from B-side to A-side IPSI, move archangel to EI
50
Interchange from A-side to B-side IPSI, move archangel to EI
60
No IPSI interchange, control (archangel) moves to A-side IPSI
70
No IPSI interchange, control (archangel) moves to B-side IPSI
80
Interchange from B-side to A-side IPSI, move archangel to IPSI
90
Interchange from A-side to B-side IPSI, move archangel to IPSI
100
Too faulted to take any action
110
Interchange from B-side to A-side IPSI, too faulted to move archangel to EI
120
Interchange from A-side to B-side IPSI, too faulted to move archangel to EI
8-956
Issue 1 May 2002
Value
Description
1
EAL fault class
2
PKT-INT fault class
3
TONE-BD fault class (not TDM-CLK)
4
TDM-CLK fault class (loss of clock)
7
Preference migration to A-side IPSI
0
This is an improvement in the previous fault class (y).
1
This is a degradation of the previous fault class (y).
Continued on next page
555-233-143