FIBER-LK (Fiber Link)
Table 8-328. Test #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
204
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 4. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 513, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 513, replace the SNI
205
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 5. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 769, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 769, replace the SNI
206
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 6. (The list fiber-link command displays a fiber link's endpoints.)
1. Perform the
2. If the SNI being tested has SNI-PEER Error Type 1025, replace the SNI
3. If the SNI being tested still has SNI-PEER Error Type 1025, replace the
555-233-143
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
in slot 4.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
in slot 5.
''Fault Isolation for Fiber Links'' on page
resolve multiple SNI-PEER errors.
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
SNI in slot 6.
4-19. This should
4-19. This should
4-19. This should