Maintenance-Object Repair Procedures
Table 8-244. Test #135 Internal Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
1039
ABORT
The DS1 Interface circuit pack is providing timing for the system. Therefore, it
cannot be reset without major system disruption.
1. If the DS1 Interface circuit pack needs to be tested, set the synchronization
2000
ABORT
The test was aborted. Response to the test was not received within the
allowable time period. This may be due to hyperactivity. Error type 1538 in the
error log indicates hyperactivity. The hyperactive circuit pack is out of service
and one or more of the following symptoms may be exhibited.
1. The DS1-BD tests (such as Tests 139 and 140) are aborting with error
2. The tests run on the ports of this circuit pack are returning a no board
3. A busyout or a release command has no affect on the test results.
4. A list config command shows that the circuit pack and the ports are
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
8-602
Issue 1 May 2002
reference to another DS1 Interface circuit pack or to the Tone-Clock circuit
via the following command sequence:
Issue the disable synchronization-switch command.
Next, issue the set synchronization UUCSS command.
Lastly, issue the enable synchronization-switch command.
code 2000.
result.
properly installed.
NOTE:
When hyperactivity occurs, the circuit pack is isolated from the system,
and all of its trunks are placed into the out-of-service state. The system
will try to restore the circuit pack within 15 minutes. When no faults are
detected for 15 minutes, the DS1 interface circuit pack is restored to
normal operation. Every DS1 interface trunk is then returned to the
in-service state. Hyperactivity is often caused by the associated facility.
In such a case, faults (such as slips, misframes, or blue alarms) would
be entered in the error log. In addition, many hardware errors would be
logged against the associated trunk circuits. If the facility is OK and the
error occurs again after 15 minutes, escalate this problem.
Continued on next page