ISDN-TRK (DS1 ISDN Trunk)
Table 8-400. Test #258 ISDN Test Call — Continued
Error
Test
Code
Result
Description / Recommendation
1116
ABORT
The switch could not appropriately change the ISDN service state.
1. Issue the status trunk group#/member# command to determine whether
2. If not, check the Error and Alarm Logs for problems with this ISDN-TRK
1117
ABORT
ISDN Service message is already outstanding.
1. Wait 2 minutes. Then try again.
1118
ABORT
Far end of ISDN trunk is not administered.
1. Check the administration of the far-end ISDN trunk.
2. Issue the status trunk group#/member# command.
3. Try the test again.
1119
ABORT
The test call was aborted due to a normal call attempt on this trunk.
1. Either wait for the normal call to finish normally, or force it to be dropped by
1120
ABORT
The DS1 ISDN Trunk is in the ISDN out-of-service/far-end state.
1. Try to change the service state via Test #256 (Service State Audit Test)
1122
ABORT
There is no test line number for the far-end switch.
1. Check the Trunk Group Administration form.
1123
ABORT
There is no Feature Access Code administration for this Facility Test.
1. Check the Dial Plan and Feature Administration forms.
2000,
ABORT
Internal system error.
2012,
1. Retry the command at 1-minute intervals up to 5 times.
None
2035
ABORT
The call has timed out, perhaps because of a lack of system resources.
1. Wait 1 minute and try again.
2036,
ABORT
Internal system error.
2037
1. Follow recommendation for ABORT code 2012.
555-233-143
a call is active on this DS1 ISDN trunk. If so, proceed as for Error Code
1119.
(DS1 ISDN Trunk) MO.
NOTE:
The test call will only be performed if the trunk is idle.
using the busyout trunk trunk-group/trunk member command to
busyout the DS1 ISDN Trunk. When the trunk is idle, retry the test.
and then try this test again. Keep in mind that the trunk may be in the
out-of-service/far-end state due to problems at the far-end switch. If that is
the case, no remedial action can be taken at this end.