Maintenance-Object Repair Procedures
Table 8-307. Test #242 Expansion Interface Lightwave Transceiver Looparound
Error
Test
Code
Result
Description / Recommendation
1002
ABORT
The system could not allocate timeslots for the test. The system may be under
heavy traffic conditions, or it may have timeslots out of service due to
TDM-BUS errors. Enter display errors and resolve any TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out of service.
1. Enter display errors and follow associated repair procedures for
2. Enter display errors and follow associated repair procedures for
3. If neither condition exists, retry the command at 1-minute intervals up to 3
1015
ABORT
The system will not allow this test to be run because the EI circuit pack has not
been busied out.
1. Busyout the EI circuit pack. Then, repeat the test board UUCSS long
1031
ABORT
If the EI circuit pack is in an PN and is on the active PNC, and is not part of an
PN-to-PN link, this test cannot be executed. If the lightwave transceiver
looparound is activated, it is impossible to deactivate it.
1. If PNC Duplication is enabled, attempt to make the standby PNC active
2. If the PNC Interchange is successful, the Lightwave Transceiver
1033
ABORT
The test cannot run because the EI circuit pack does not have a fiber link
administered to it and there is not sufficient data to run the test.
1. Issue the list fiber-link command to verify that there is no fiber link
2. If there is no fiber administered to this circuit pack (but should be), add the
3. Retry the command.
8-800
Issue 1 May 2002
retry the command at 1-minute intervals up to 3 times.
TTR-LEV. Even if there are no TTR-LEV errors, there may not be a Tone
Detector available on the network that contains the circuit pack being
tested. Verify that there is at least one Tone Detector on this network. If
there is not at least one Tone Detector, this test always aborts for this EI
board. This will not harm the system.
TONE-PT.
times.
command.
through the reset pnc interchange command.
Looparound test may now be executed on the original EI circuit pack.
administered to this circuit pack.
correct fiber using the add fiber-link command.
Continued on next page
555-233-143